Topic: Refrigeration and Air Conditioning

The heat removal rate from a refrigerated space is 7.2 kW and the power input to the compressor is 1.8 kW. The coefficient of performance (COP) of the refrigerator is

  • A. 4
  • B. 5
  • C. 1.25
  • D. 0.25

Answer: A. 4

Explanation: COP of refrigerator = Heat removed from space / Work done = 7.2 / 1.8 = 4.