ISRO Mechanical & Aerospace 2026 - Question 23

All ISRO Mechanical & Aerospace papers | ISRO Mechanical & Aerospace 2026

Topic: Thermodynamics / Refrigeration

In an aqua-ammonia vapour absorption refrigeration system, the rectifier dephlegmator is utilized immediately after the generator to:

  • A. Condense completely the ammonia vapor before expansion
  • B. Sub cool the liquid ammonia to increase the refrigerating effect
  • C. Absorb the ammonia vapor into the weak solution
  • D. Remove the water vapor from the ammonia-water mixture leaving the generator

Answer: D. Remove the water vapor from the ammonia-water mixture leaving the generator

Explanation: The vapor leaving the generator consists of both ammonia and a small amount of water vapor. The rectifier (or dephlegmator) cools this mixture to condense the water vapor out, preventing water from reaching and freezing in the expansion valve and evaporator.