ISRO Mechanical & Aerospace 2009 - Question 3

All ISRO Mechanical & Aerospace papers | ISRO Mechanical & Aerospace 2009

The correct sequence of the centrifugal pump components through which the fluid flows is

  • A. Impeller, Suction pipe, Foot valve and strainer, Deliver pipe
  • B. Foot valve and strainer, Suction pipe, Impeller, Deliver pipe
  • C. Impeller, Suction pipe, Deliver pipe, Foot valve and strainer
  • D. Suction pipe, Deliver pipe, Impeller, Foot valve and strainer

Answer: B. Foot valve and strainer, Suction pipe, Impeller, Deliver pipe

Explanation: The flow sequence starts from the sump: Foot valve & strainer $\rightarrow$ Suction pipe $\rightarrow$ Impeller $\rightarrow$ Delivery pipe.

| | All questions of ISRO Mechanical & Aerospace 2009