ISRO Mechanical & Aerospace 2009 - Question 6

All ISRO Mechanical & Aerospace papers | ISRO Mechanical & Aerospace 2009

A necessary precaution in selection of pumps for parallel operations is that:

  • A. H-Q characteristics of both should be identical
  • B. Both pumps should be centrifugal type
  • C. Both pumps should be identical
  • D. There should not be change from positive to negative slope in H-Q curve

Answer: A. H-Q characteristics of both should be identical

Explanation: For stable parallel operation, pumps should have matching Head-Discharge (H-Q) characteristics to ensure load sharing and prevent one pump from overpowering the other.

| | All questions of ISRO Mechanical & Aerospace 2009