Topic: Microwave Engineering
For L-section matching network as shown in the circuit below, what will be the value of L to match resistive load of 200 Ω to 100 Ω source operating at 1000 Mrad/s?
- A. 50 nH
- B. 50/π nH
- C. 100 nH
- D. 100/π nH
Answer: C. 100 nH
Explanation: To match a load $R_L = 200 \Omega$ to a source $R_S = 100 \Omega$ using an L-section (series L, shunt C), we first find the network quality factor $Q = \sqrt{\frac{R_L}{R_S} - 1} = \sqrt{\frac{200}{100} - 1} = \sqrt{2-1} = 1$. The series element reactance is $X_L = Q \times R_S = 1 \times 100 = 100 \Omega$. Since $X_L = \omega L$, we solve for $L$: $L = \frac{X_L}{\omega} = \frac{100}{1000 \times 10^6} = 10^{-7} \text{ H} = 100 \text{ nH}$.