Topic: Network Theory / Resonance
A parallel RLC circuit has an unloaded Q of 2000 and R = 100 Ω. When a load of 75 Ω is connected to the resonator, the loaded Q of the resonator is
- A. 8000/7
- B. 6000/7
- C. 4000/5
- D. 3000/π
Answer: B. 6000/7
Explanation: For a parallel RLC tank circuit, the quality factor is directly proportional to its equivalent parallel resistance ($Q = R_{eq}/(\omega L)$). Therefore, $\frac{Q_{loaded}}{Q_{unloaded}} = \frac{R_{loaded}}{R_{unloaded}}$.
Given $R_{unloaded} = 100 \Omega$ and an external load of $75 \Omega$ is added in parallel, the new loaded resistance is $R_{loaded} = \frac{100 \times 75}{100 + 75} = \frac{7500}{175} = \frac{300}{7} \Omega$.
The loaded quality factor is $Q_{loaded} = Q_{unloaded} \times \left( \frac{R_{loaded}}{R_{unloaded}} \right) = 2000 \times \left( \frac{300/7}{100} \right) = 2000 \times \frac{3}{7} = \frac{6000}{7}$.