Match list-I (welding effect) with list-II (causes): A. Spatter B. Distortion C. Slag inclusion D. Porosity vs 1. Damp electrodes 2. Arc blow 3. Improper cleaning 4. Poor joint selection
- A. A-2, B-4, C-3, D-1
- B. A-4, B-2, C-1, D-3
- C. A-2, B-4, C-1, D-3
- D. A-4, B-2, C-3, D-1
Answer: A. A-2, B-4, C-3, D-1
Explanation: Spatter-Arc blow; Distortion-Joint design; Slag-Cleaning; Porosity-Dampness.