Section: Thermodynamics | Type: NAT | Marks: 1

Following data is for an actual vapour compression refrigeration cycle. Enthalpy at compressor inlet: 246⁡kJ/kg Enthalpy at compressor exit: 286⁡kJ/kg Heat load on the evaporator: 158⁡kJ/kg The enthalpy at the exit of the condenser in kJ/kg is ________ (rounded off to the nearest integer).

Answer: 88