GATE XE (Engineering Sciences) 2012 - Question 70

All GATE XE (Engineering Sciences) papers | GATE XE (Engineering Sciences) 2012

Section: Thermodynamics | Marks: 1

If L Q represents the magnitude of heat transfer from a low temperature reservoir to a cyclic device and H Q represents the magnitude of heat transfer from a cyclic device to a high temperature reservoir, then for the same L Q and H Q , the coefficient performance of a refrigerator ( ) R COP and the coefficient performance of a heat pump ( ) HP COP can be related as

Figure for question 70, GATE XE (Engineering Sciences) 2012

  • A. 1 R HP COP COP =−
  • B. 1 HP R COP COP = +
  • C. . 1 R HP COP COP =
  • D. 1 HP R COP COP = −

Answer: B. 1 HP R COP COP = +

| | All questions of GATE XE (Engineering Sciences) 2012