Topic: Thermodynamics / Power Cycles
In a Rankine Cycle, implementing regenerative feed water heating improves the cycle's thermal efficiency by:
- A. Increasing the average temperature at which heat is added to the cycle
- B. Decreasing the average temperature at which heat is rejected from the cycle
- C. Increasing the total work output of the steam turbine
- D. Decreasing the pump work required
Answer: A. Increasing the average temperature at which heat is added to the cycle
Explanation: Regenerative feed water heating extracts a portion of partially expanded steam from the turbine and uses it to preheat the liquid water leaving the pump before it enters the boiler. By entering the boiler at a higher temperature, the average temperature of external heat addition increases, which directly increases the Carnot efficiency equivalent and overall cycle thermal efficiency.