ISRO Electronics & Communication (ECE) 2026 - Question 63

All ISRO Electronics & Communication (ECE) papers | ISRO Electronics & Communication (ECE) 2026

Topic: Power Electronics

A 3 phase fully controlled thyristor bridge converter is used as a line commuted inverter to feed 420 V DC (100kW power) to a 3 phase 415V, 50 Hz AC mains. Consider DC link current to be constant, then average current of thyristor is

  • A. 26.45 A
  • B. 45.82 A
  • C. 79.37 A
  • D. 137.46 A

Answer: C. 79.37 A

Explanation: First, calculate the constant DC link current: $I_{dc} = \frac{P}{V_{dc}} = \frac{100,000 \text{ W}}{420 \text{ V}} \approx 238.095 \text{ A}$. In a 3-phase fully controlled bridge converter, each thyristor conducts for $120^{\circ}$ (which is one-third of the $360^{\circ}$ cycle). Therefore, the average current flowing through a single thyristor is $I_{T(avg)} = \frac{I_{dc}}{3} = \frac{238.095}{3} \approx 79.365 \text{ A}$, matching option (c).