Topic: Analog Circuits
In industrial signal conditioning, a voltage signal is often susceptible to Electromagnetic Interference (EMI). What OPAMP configuration is commonly used at receiver end to reject Common Mode Noise?
- A. Inverting amplifier
- B. Non-inverting amplifier
- C. Differential amplifier
- D. Voltage follower
Answer: C. Differential amplifier
Explanation: EMI typically induces noise identically on both signal wires of a twisted pair, creating Common Mode Noise. A differential amplifier amplifies the difference between the two input voltages while significantly rejecting any signals common to both inputs, characterized by a high Common-Mode Rejection Ratio (CMRR).