Topic: Control Systems
Bode magnitude plot of the transfer function $G(s) = \frac{K(1+0.5s)^2(1+as)}{s(1+s)(1+0.125s)(1+bs)(1+0.03125s)}$ is shown below. The value of $\frac{bK}{a}$ is
- A. 2
- B. 4
- C. 8
- D. 16
Answer: C. 8
Explanation: From the slope changes on the Bode plot, we identify the corner frequencies. The slope increases by +20 dB/dec at $\omega = 4$, implying a zero at $s = -4$, so $a = 1/4 = 0.25$. The slope decreases by -20 dB/dec at $\omega = 16$, implying a pole at $s = -16$, so $b = 1/16 = 0.0625$. The ratio $b/a = 0.0625/0.25 = 1/4$. From the plot's y-axis, the flat magnitude segment between $\omega=8$ and $\omega=16$ rests above 20 dB, corresponding to $|G| = K/2 = 16 \implies K = 32$. Therefore, $\frac{bK}{a} = \frac{1}{4} \times 32 = 8$.