ISRO Electrical Engineering (EE) 2023 - Question 73

All ISRO Electrical Engineering (EE) papers | ISRO Electrical Engineering (EE) 2023

In an inverter with fundamental output frequency of 50 Hz, if third harmonic is eliminated, then frequencies in Hz of other components in the output voltage would be

  • A. 250, 350, 500, high frequencies
  • B. 250, 350, 550, high frequencies
  • C. 50, 100, 350, 550
  • D. none of these

Answer: B. 250, 350, 550, high frequencies

Explanation: With 3rd harmonic eliminated in a 50 Hz inverter, remaining odd harmonics are 5th (250 Hz), 7th (350 Hz), 11th (550 Hz), and higher.